News Center
Micafluid Converter Station Components Detection

Micafluid Converter Station Components Detection

SF6 is known for its high electric insulating characteristic, and it is widely used as an insulating gas in power substation facilities, electric transformers and electric current breakers. Execution of Turn Key Projects for Fixed/ Online Gas Detectors. On-site Calibration and Maintenance of Fixed Gas Detection System of any make. Get Price

[email protected]
News Detail
  • MindSphere Application – SFC Analyzer

    Converter stations create various amounts of data in con-verter modules, cooling systems, transformers, ventilation systems, protection devices, the local HMI and even the fire detection system. It is possible to connect further devices and use different protocol types to access data from other modules. According to your preferences the connectivity

    Get Price
  • HVDC PLUS – the decisive step ahead

    for all key components of the converter control. • Standard control and protection system; hardware and software in hot standby and proven in practice • Minimized maintenance and service requirements • Compact station design with little high-voltage equipment

    Get Price
  • UHV Converter Stations and the Main Electrical Equipment

    Jan 01, 2018UHVDC Converter Stations With Three 12-Pulse Converters Per Pole16.1.3.1. Electrical Structure. Converter stations configured with three series-connected 12-pulse converters per pole refer to those with three 12-pulse converters connected in series per pole. Similarly, the three 12-pulse converters may be at the same voltage level.

    Get Price
  • CONTROL AND PROTECTION SYSTEM FOR HVDC

    For this test, the DC line/cable is disconnected from the remote converter station. Then the DC voltage is slowly increased up to the maximum level via a ramp at the testing station. Deblocking of the converter is managed by the Deblock Sequence in a coordinated manner between both stations utilizing interstation telecommunication.

    Get Price
  • Non-communication based protection scheme using

    Fault detection is quickly retained by current harmonics at each terminal of converter stations of the MTDC networks without physical communication among the terminals. The modulated scheme is also adept of discriminating external fault from internal by counting the number of pulse count in a specific time interval of 6 ms of the voltage harmonics.Author: Muhammad Haroon Nadeem, Xiaodong Zheng, Nengling Tai, Mehr Gul, Moduo Yu, Moduo Yu, Yangyang He

    Get Price
  • Grid West Project HVDC Technology Review

    EirGrid Grid West Project HVDC Technology Review Page 2 of 123 Revision Table Revision Issue Date Description 0 12/12/2014 Final for Approval 1 17/12/2014 Client Comments Addressed

    Get Price
  • Wavelet-based protection strategy for DC faults in

    The other converter stations are operating in active power control mode. At the AC side, all converter stations create a AC grid voltage, controllable in amplitude and in phase, at their terminals. Fig. 5 Wavelet coefficients of cable voltages at VSC1 for FLT-12- The system is represented by the parameters given in the m-PP and FLT-43-3-PP

    Get Price
  • High Power Conversion Technology for High Voltage DC

    The converter valve of the MMC has been constructed with the advantages of high modularity, low power loss, and excellent voltage capacity expansion. Power sub-module ±320kV/1000 MW converter valve ±30kV/20 Valve hall of MMC-HVDC MW converter valve ±200kV/400 MW converter valve Development of converter valve

    Get Price
  • Transmission and Distribution Archives | EEP - Electrical

    Feb 24, 2021Major components of the HVDC converter station (single line diagram explained) This technical article examines in detail the main equipment of an HVDC converter station and discusses the layout of this equipment within the converter station. The interconnection of HVDC to… Read more. Apr 29, 2020 | By Edvard

    Get Price
  • Longquan 220kV Substation - Bentley

    Project. In the western region of Xingtai in Hebei, China, a Longquan 220-kilovolt substation is being built to resolve power supply issues. The CNY 94.7 million project was challenging, however, due to its location in a rugged topographical area that included elevation differences up to 11 meters.

    Get Price
  • Wavelet-based protection strategy for DC faults in

    The final objective is to implement a protection algorithm which allows to detect a DC fault within 1 ms without using communication between the participating converter stations. Protection system

    Get Price
  • SF6 positive DC partial discharge decomposition

    The component detection system adopted the SHIMADZU QP2010Ultra gas chromatography‐mass spectrometry (GC/MS) device for the quantitative analysis of the SF 6 decomposition components. The instrument adopted helium gas with a purity of 99.9995% as carrier gas; the chromatographic column box temperature was 40&C; the column flow rate was 1.2 mL/min; the diversion ratio was 30:1; and the

    Get Price
  • Influence of lightning surges on wideband‐frequency model

    Oct 12, 2020The detection and clear understanding of faulty signals pertaining to transient frequency characteristics have vital significance in the context of designing the converter station equipment, especially for the EM immunity of secondary devices and sensitivity issues of the present‐day relay protection systems.

    Get Price
  • Virtual Difference Voltage Scheme for Fault Detection in

    In this paper, a fast fault detection scheme for voltage source converter based high-voltage direct current (VSC-HVDC) transmission systems is proposed. based on the 1-mode components, which

    Get Price
  • Frequency domain based DC fault analysis for bipolar HVDC

    Jul 10, 2017The converter station is assumed to be ungrounded considering that if the converter station is low-impedance or solidly grounded, the influence on the negative pole is insignificant or non-existent. Figure 6 gives the bode plots of the transfer functions in absolute magnitude. Figure 7 gives the step responses of the transfer functions up to 1

    Get Price
  • WO2013079937A2 - Power converter - Google Patents

    A Voltage Sourced Converter, VSC, for a High Voitage Direct Current, HVDC, power converter, the VSC comprises a bridge circuit for each of one or more phases of an AG network. The bridge circuit has two arms, each arm connecting the supply to a pole of a DC terminal, wherein each arm of the bridge circuit has one or more semiconductor modules capable of being switched between an on-condition

    Get Price
  • HVDC Technology for Large Scale Offshore Wind

    The high-voltage converter equipment weighs around 2000 metric tons, and for the sending station is located on offshore platforman (refer to section6). All equipment the for offshore station is installed indoors while for the onstation all shore DC equipment is installed indoors. These choices ensure safe

    Get Price
  • US20130088802A1 - Fault protection of hvdc transmission

    A protection system for high voltage direct current, HVDC, transmission lines is provided. The protection system includes a direct current, DC, bus, a device configured to connect an HVDC transmission line to the bus, at least one DC circuit breaker arranged for disconnecting the transmission line from the bus upon reception of a trip signal, current and voltage sensors, an inductor arranged

    Get Price
  • FAULT ANALISIS IN HVDC HVAC TRANSMISSION LINE

    Dec 15, 2017The various faults occurs at the converter station of a HVDC system and HVDC and the HVAC systems 3 1.3 Advantages and inherent problems associated with HVDC 4 1.4 Economic comparison 7 1.5 Components of an HVDC transmission system 8 1.6 Types of HVDC systems or configuration 11 1.7 Comparison of HVDC link and HVAC link 15 Chapter 2 2.1

    Get Price
  • Design Challenges for Numerical SSR Protection

    converter station for HVDC link to Finland is also located in the vicinity of Forsmark NPP. At the Forsmark NPP-site there are three boiling water reactors designed by Asea-Atom. Forsmark 1 entered into commercial operation in 1980, while Forsmark 2 began operating commercially in 1981. Forsmark 3

    Get Price
  • Hybrid High-voltage Direct Current Breaker | Utility Products

    The higher voltage rating is accomplished by connecting in series several main breaker cells, but the switching stress per cell is the same as in the demonstrator. Tests have been performed for normal breaking events and situations with failed components in the breaker to verify reliable detection and safe operation in such cases.

    Get Price
  • Components of HVDC | High Voltage Direct Current | Capacitor

    Apr 19, 2015Converter Transformer Valve Hall AC Harmonic Filters Shunt Capacitors DC Harmonic Filters Smoothing Reactors DC Current / Voltage measuring devices Valve Cooling / Ventilation System Valve Timing PT VESDA Electrode Station Repeater Station Basic Components of HVDC Terminal Converter Xmers AC Harmonic 400 kV filters. DC Line. Smoothing Reactor

    Get Price
  • Detector for Substation

    SF6 is known for its high electric insulating characteristic, and it is widely used as an insulating gas in power substation facilities, electric transformers and electric current breakers. Execution of Turn Key Projects for Fixed/ Online Gas Detectors. On-site Calibration and Maintenance of Fixed Gas Detection System of any make. Get Price

    Get Price
  • DC fault analysis for modular multilevel converter-based

    Jan 12, 2016DC fault protection is the key technique for the development of the DC distribution and transmission system. This paper analyzes the transient characteristics of DC faults in a modular multilevel converter (MMC) based DC system combining with the numerical method. Meanwhile, lots of simulation tests based on MATLAB/Simulink are carried out to verify the correctness of the theoretical analysis.

    Get Price
  • On-line Fault Detection to Prevent Network Failure | TD

    The fault location technology consists of two modes: Mode 1 is a trigger monitoring system and Mode 2 is a real-time monitoring system installed in each local converter station, where the real-time load current and fault current are monitored simultaneously at Modes 1 and 2 to detect and locate the fault point.

    Get Price
  • Home | United Kingdom | United Kingdom

    Population growth, rapid urbanization and climate change put our urban infrastructure under pressure. Siemens’ technologies can help cities respond to these challenges with innovative solutions and our expertise in the areas of electrification, automation, and digitalization.

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online