Siemens' scope of supply comprises much more than the high-voltage equipment that is required for the operation of a substation. It includes high- and medium-voltage switchgear, transformers, and equipment as well as all ancillary systems for control, protection, communication, and condition monitoring.

[email protected]
News Detail
  • gis substation testing - wilcokats.nl

    gis substation testing. GIS Substation Testing Trolley. GIS Substation testing trolley Please Contact us for More Detail. Read More. DC High Voltage Test Set - Portable (Hipot) Portable DC High Voltage Test Set is used for testing the underground cable for knowing the condition of cable-leakage at High Voltage.

    Get Price
  • Gas-insulated switchgear | Transmission Products | Siemens

    The Siemens range of gas-insulated switchgear (GIS), for rated voltages from 72.5 kV up to 550 kV, is an extremely successful product concept. Since its introduction back in 1968, Siemens has installed switch fields in all climatic zones of the earth, recording

    Get Price
  • CONSTRUCTION DESIGN FEATURES OF GAS INSULATED SYSTEM (GIS)

    • Leak testing • Mechanical or (VFTO) is a unique electromagnetic transient phenomenon occurring in Gas Insulated Substation (GIS), which determines the insulation level of the GIS (above

    Get Price
  • High-voltage substations | Power Transmission | Siemens

    Siemens’ scope of supply comprises much more than the high-voltage equipment that is required for the operation of a substation. It includes high- and medium-voltage switchgear, transformers, and equipment as well as all ancillary systems for control, protection, communication, and condition monitoring.

    Get Price
  • An Introduction to Gas Insulated Electrical Substations

    2020-10-6This course provides an brief introductory overview of (GIS) or Gas Insulated Substations. A gas insulated substation (GIS) is a high voltage substation in which the major conducting structures are contained within a sealed environment with a dielectric gas known as SF6, or sulfur hexafluoride gas as the insulating medium.

    Get Price
  • Gas-Insulated Substations - GIS

    2021-3-7Superior Dielectric Gas. A gas-insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase-tophase and phase-to-ground insulation.The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures.

    Get Price
  • Blue gas-insulated switchgear | References | Siemens

    The blue GIS 8VN1 from Siemens is an innovative, compact switchgear product. 8VN1 doesn’t use Sulfur hexafluoride (SF6 gas) or other fluorine gases as an insulating and interrupting medium. Instead of greenhouse gases, it uses compressed synthetic air (so called clean air) technology to provide insulation between live parts and the earthed

    Get Price
  • Digital Substation - Global | Siemens Global

    Digital Substation - Creating a more secure, efficient and modern electricity system Hydro-Québec selected Siemens to modernize the protection and control system at its Saint-Chrysostome substation. From automation to cybersecurity, the power utility is

    Get Price
  • LNG Carrier Cargo Tank Tightness Test - SGS

    2016-2-17LEAK TEST METHODS n Ammonia (NH3) Leak Testing This test is performed by introducing an inert gas mixed with ammonia to the internal space of the test material and then over-pressurising. After ammonia sensitive paint is spread over the welding seams to be tested, the inert nitrogen/ammonia mixture gas is fed internally through the test