News Center
iso SF6 Charging

iso SF6 Charging

I.Overview. SF6 gas recovery and purification charging and discharging device is used for the manufacturing plant of SF6 gas insulation electrical equipment. In the departments of use, operation and scientific research, various electrical equipment is vacuumized, SF6 gas is filled into the electrical equipment, and SF6 gas is recovered from the ...

[email protected]
News Detail
  • High Vacuuming Speed SF6 Gas Recovery Purification Filling

    I.Overview. SF6 gas recovery and purification charging and discharging device is used for the manufacturing plant of SF6 gas insulation electrical equipment. In the departments of use, operation and scientific research, various electrical equipment is vacuumized, SF6 gas is filled into the electrical equipment, and SF6 gas is recovered from the5/5

    Get Price
  • China Equipment Sf6 Gas Recovery-Charging Device - China

    HZHS-515 type SF6 gas recovery device is an integrated recovery device. The device is composed of a recovery system, a vacuum pumping system, a cleaning system, a storage system and a condensing system. Product Features: 1.Adopt advanced principle and technology, advanced design, complete function, reasonable structure, simple operation.

    Get Price
  • China LW3-10 Outdoor High Voltage SF6 Circuit Breaker

    LW3-10 I II III type outdoor SF6 circuit breakers adopt SF6 gas as rec-extinguishing and insulating medium, which is applied to self-rotated arc extinguishing theory Operating mechanism is divided into I type hand charging spring operaring mechanism, II type motor charging spring operating mechanism and III type DC electromagnetic operating

    Get Price
  • Factory Price High Voltage Ac 126kv 132kv 145kv Sf6

    Rated line charging close current: A: 31.5: 16: Rated operation sequence : O-0.3s-CO-180s-CO35: 17: Main circuit resistance : μΩ ≤35: 18: Rated SF6 gas pressure : MPa: 0.6: 19: SF6 gas leakage rate : ppm ≤0.55: 20: Moisture content of SF6 gas (V/V) ≤150: 21: Mechanical life: times: 10000: 22: Electric distance : Phase to earth: mm: 3906/3150: Phase to phase: 3906/3150: 23

    Get Price
  • Vacuum Pump Sf6 Gas Recovery Discharging Injection

    The recycling device is suitable for SF6 electrical equipment and GIS combined electrical equipment. According to DL/T662-1999 Sulfur Hexafluoride Inflator and Recovery Device,the device is composed of recycling system, gas charging system, vacuum pumping system, purification system and gas storage system, with the following main functions: 1.

    Get Price
  • Outdoor SF6 Circuit Breaker - Type OHB

    2021-2-17charging : To manually charge the closing springs, it is necessary to fully insert the charging lever into the seat (9) and turn it clockwise until the yellow indicator (6) appears. The force which can normally be applied to the charging lever fitted is 130 N. In any case, the maximum force applied must not exceed 170 N. b) Electrical operation for spring

    Get Price
  • China Full Sf6 Gas Insulated Ring Main Unit Switchgear

    Rated cable charging breaking current: A: 50(C) 7: Rated cable charging breaking current: A: 10(C) 8: Rated excitation transformer breaking current: A: 16: 9: Rated making current peak: KA: 50/2.5(/) (main switch/earth) 10: Rated peak withstand current: 11: Rated short time withstand current: 20: 12: Rated short time withstand time: S: 4: 13: Mechanical life: times: C/F(2000)V(10,000)

    Get Price
  • circuit breaker - Schneider Electric

    2019-1-12SF6 pressure signalisation / common point for end of charging signalisation and opened or closed CB signalisation supervision of continuity release circuit J: signalisation pression SF6 / point commun pour signalisation commande armée et signalisation disj.

    Get Price
  • Sulfur hexafluoride (SF6) Recycling Program for Out of

    2016-2-17Standard Operating Procedure SF6 • SET Crew mobilizes to Substation and places job trailer near interrupters to be recycled. • Interrupters are staged in an area by Exelon prior to our crews arrival. • No recovery shall be conducted on an interrupter that is still in service. • Utilizing Vacuum recovery system crew removes SF6 through a

    Get Price
  • Gas Filling Equipment – SF6 Pressure Regulators | Concorde

    2021-2-24Our SF6 gas regulators are made of stainless steel which promises durability and a quality product. The diaphragm, however, is made of hastelloy steel, a nickel-based steel alloy which exhibits high resistance to corrosion and oxidization.

edge-iconRelated News