A system for detecting the presence of an average dc current component in a load comprising a current transformer 10 for supplying a signal representative of the current, and a comparison means 12 and 13, for example a microprocessor and associated RAM, for comparing values of the current taken at time intervals corresponding to a phase interval of substantially nπ, where nπ is an odd ...

[email protected]
News Detail
  • Current Transformers Saturation Detection and

    Derivative-based approaches have been widely used for current-transformer (CT) saturation detection. Previous approaches dealt with the magnitude of current derivatives.

    Get Price
  • Current Transformer Saturation Detection Using Gaussian

    2017-2-9Current Transformer Saturation Detection Using Gaussian Mixture Models, M. Moghimi Haji et al. / 79 r87 82 Vol. 11, February 2013 the hysteresis loop and Man is the unhysteretic magnetization provided by the Langevin function.

    Get Price
  • Current Transformers’ Saturation Detection and

    2018-6-26Fig. 2. The current transformer model [14] drop in a real CT which is saturated. This problem can lead to mal-operation of the protective relays. Therefore, it is necessary to present a methodology for detection and compensation of the CT saturation. 2.2 Analytical denition Fig. 2 shows the current transformer model by us-

    Get Price
  • DC current detection system for a current transformer

    A system for detecting the presence of an average dc current component in a load comprising a current transformer 10 for supplying a signal representative of the current, and a comparison means 12 and 13, for example a microprocessor and associated RAM, for comparing values of the current taken at time intervals corresponding to a phase interval of substantially nπ, where nπ is an odd

    Get Price
  • Current Transformer Saturation Detection Using

    2020-10-5Current Transformer Saturation Detection Using Gaussian Mixture Models, M. Moghimi Haji et al. / 79 ‐ 87 Journal of Applied Research and Technology 87

    Get Price
  • Current Transformer Saturation Detection Using Gaussian

    2013-2-1Current transformer (CT) saturation distorts the secondary current and in consequence leads to operating delay or malfunction of protection relays (e. g. under reaching of over current relays, overestimation of fault loop impedance in distance relays) . Therefore an appropriate saturation detection method is necessary to maintain the protection

    Get Price
  • Winding Fault Detection of Transformer using

    2019-7-1Winding Fault Detection of Transformer using Symmetrical Components Theory . Ms. Prerna H. Suryawanshi . on detecting failures of transformers before unexpected machine The concept that the secondary line current of transformer does not show much variation even if the fault is

    Get Price
  • Detection of inrush current in distribution transformer

    2005-6-1Moreover the second harmonic components in the magnetizing inrush current tend to be relatively small in new transformer because of improvement in the transformer core material . Some schemes make use of the information obtained from the variation of transformer terminal voltages, such as method based on voltage restraint principle.

    Get Price
  • Transformer PD Detecting and Positioning System - PD

    The system supports a pulse current,ultrasonic, high frequency, ultra high frequency PD detection mode, it can detect the partial discharge status of the transformer, identify the partial discharge point of the transformer.

    Get Price
  • Learning RoI Transformer for Detecting

    Translate this page2019-7-14Learning RoI Transformer for Detecting Oriented Objects in Aerial ImagesJian Ding, Nan Xue, Yang Long, Gui-Song Xia, Qikai LuWuhan University,WHU:武汉大学,武大Computational and Photogrammetric Vision Tea...

edge-iconRelated News