LNG Carrier Cargo Tank Tightness Test - SGS2016-2-17LEAK TEST METHODS n Ammonia (NH3) Leak Testing This test is performed by introducing an inert gas mixed with ammonia to the internal space of the test material and then over-pressurising. After ammonia sensitive paint is spread over the welding seams to be tested, the inert nitrogen/ammonia mixture gas is fed internally through the test

[email protected]
News Detail
  • Guide to Good Leak Testing - US EPA

    2013-2-4Guide to good leak testing Commercial and industrial refrigeration and air conditioning systems leak too much refrigerant – leaks of up to 30% of the charge during a year are not uncommon. Leak rates do not have to be this high. Adherence to best practice in service, maintenance leak testing and repair can significantly reduce refrigerant losses.

    Get Price
  • Electrical test, maintenance measurement products | Megger

    Earth testing; Leak and corona detectors; Low resistance ohmmeters PD testing on switchgear (AIS/GIS/GIL) PD testing on bushings, spacer and insulators. Multifunction installation testers. Multimeters and clampmeters. Portable appliance testing (PATs) Software for testing and maintenance. Utility service detection. Battery testing

    Get Price
  • Electrical test, maintenance measurement products | Megger

    Tests can be conducted on-line, on a continuous basis or during maintenance to provide all round condition monitoring of the asset. Power, distribution and instrument transformers Partial discharge testing is an essential, proven tool that can locate and identify flaws in the insulation of cables, bushings, windings, tap changers and a myriad

    Get Price
  • Anastomotic Leak Testing After Colorectal Resection: What

    Anastomotic leak testing was performed more commonly in stapled anastomoses (804 of 899; 89.4%) than in handsewn anastomoses (21 of 99; 21.2%). Anastomotic leak testing yielded positive results in 65 of 825 tested anastomoses (7.9%), whereas 760 of 825 anastomoses (92.1%) were airtight.

    Get Price
  • Electricians software for testing and maintenance

    Megger offers a complete range of software for the certificating contractor under the name PowerSuite. Whether you are working in 18th Edition installations, Part P or Portable Appliance Testing, PowerSuite can increase your efficiency.

    Get Price
  • Electrical test and maintenance equipment

    The world is changing and the energies which power our daily lives are changing too. Future demand for new and cleaner forms of power, including how we use them, requires a more agile, open minded, innovative, future looking, even star-gazing approach.

    Get Price
  • LNG Carrier Cargo Tank Tightness Test - SGS

    2016-2-17LEAK TEST METHODS n Ammonia (NH3) Leak Testing This test is performed by introducing an inert gas mixed with ammonia to the internal space of the test material and then over-pressurising. After ammonia sensitive paint is spread over the welding seams to be tested, the inert nitrogen/ammonia mixture gas is fed internally through the test

    Get Price
  • Primary injection test systems - Megger

    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker.

    Get Price
  • Frequently asked high voltage circuit breaker testing

    These vary by type of CB, manufacturer, and the type of application the circuit breaker is utilized in. It is best to consult the circuit breaker manual to determine proper maintenance and testing schedule. It is common to have 1, 3 or 5, and 10 year maintenance intervals for different types of tests to be performed.

    Get Price
  • HOSE USE, CARE AND MAINTENANCE - Goodall Hoses

    2014-10-1HOSE USE, CARE AND MAINTENANCE GENERAL INSTRUCTIONS FOR HOSE HYDROSTATIC TESTING AND INSPECTION A hydrostatic test should be made at periodic intervals to determine if a hose is suitable for continued service. This testing is to be performed in an environment that protects personnel and property from any unexpected failure.