News Center
detecting GIS Insulated Equipment

detecting GIS Insulated Equipment

Dec 04, 2017Gas-insulated switchgear (GIS) is a common electrical equipment, which uses sulfur hexafluoride (SF6) as insulating medium instead of traditional air. It has good reliability and flexibility. However, GIS may have internal defects and partial discharge (PD) is then induced. PD will cause great harm to GIS and power system.

[email protected]
News Detail
  • Mechanical defect identification for gas‐insulated

    It can even cause equipment insulation breakdown and short circuit . However, the current research on internal defects of GIS mainly focuses on partial discharge [4-7], and the traditional detection of GIS mechanical defects only focuses on the vibration characteristics of the high voltage circuit breaker . There are few researches on the abnormal vibration of GIS equipment due to mechanical defects in stable

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon

    9 mins readSep 30, 2020Crowcon F-Gas SF6 Gas Detector. The Crowcon F-gas detector for sulphur hexafluoride (SF6) is ideal for GIS switchgear applications and is part of the Crowcon fixed gas detector range. Crowcon F-gas provides a lower total cost of ownership by providing fast, stable and dependable SF6 gas detection performance with infrared technology.

    Get Price
  • Mechanical defect identification for gas‐insulated

    Mechanical failure of GIS can lead to temperature rise, insu-lation aging or gas leakage. It can even cause equipment insulation breakdown and short circuit [3]. However, the current research on internal defects of GIS mainly focuses on partial discharge [4–7], and the traditional detection of GIS mechanical defects only focuses on the vibration characteristics of the high voltage circuit breaker [8].

    Get Price
  • Typical Internal Defects of Gas-Insulated Switchgear and

    Dec 04, 2017Gas-insulated switchgear (GIS) is a common electrical equipment, which uses sulfur hexafluoride (SF6) as insulating medium instead of traditional air. It has good reliability and flexibility. However, GIS may have internal defects and partial discharge (PD) is then induced. PD will cause great harm to GIS and power system.Cited by: 3

    Get Price
  • Helium Leak Detection Systems - Telstar

    4 mins readGas Insulated Switchgears (GIS) Gas Insulated Switchgears are a very specific and demanding application for our leak detection systems. Medium and high voltage switchgears use an isolating gas inside to avoid voltage breakdown.

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F-Gas

    Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV-220kV. Detectors are located inside protected switchgear rooms to provide accurrate monitoring of gas concentrations - usually located in the local gas detection panel, fire protection system or control panel.

    Get Price
  • CN102262194A - Method for detecting internal faults of c

    The method is characterized by comprising the following steps of: judging whether the faults occur or not and determining the types of the faults according to product components generated after the...GIS

    Get Price
  • An Introduction to Gas Insulated Electrical Substations

    all equipment is much less than that of an AIS or air insulated substation . The total space required for a GIS is roughly a tenth of that needed for a conventional AIS facility. While the conventional, AIS requires several feet of air insulation to isolate a conductor, SF6 gas insulation only needs inches, allowing a GIS facility to fit into

    Get Price
  • US6333715B1 - Partial discharge detector of gas-insulated

    The present invention relates to a partial discharge detector for a gas insulated apparatus, in particular, to a partial discharge detector suitable for detecting occurrence of a partial discharge...

    Get Price
  • Preparation and Application of TiO2 Nanotube Array Gas

    Preparation and Application of TiO2 Nanotube Array Gas Sensor for SF6-Insulated Equipment Detection: a Review Nanoscale Res Lett. 2016 Dec;11(1):302. doi: 10.1186/s11671-016-1516-4. Epub 2016 Jun 18. Authors Xiaoxing Zhang 1GIS

    Get Price
  • Review on Partial Discharge Detection Techniques

    Currently, the most popular method for detecting PD in the high voltage transformer and other equipments such as the GIS is the optical detection method which uses the fiber intrinsic sensor coil, the detail of which is shown in Fig. 5(a). The fiber intrinsic sensor coil is made by winding 8 m of fiber around a former into a coil of 25

    Get Price
  • Gas-insulated Switchgear (GIS) Testing - OMICRON

    When commissioning GIS, it is also necessary to perform a voltage withstand test in line with the standards (IEC 62271-203). To this end, we have developed a testing system with which you can demonstrate that the quality of the insulation matches the rated voltage.

    Get Price
  • “GIS-DM” – Gas-Insulated Switchgear and HV Cables

    six measurement channels of the “GIS-DM” monitoring system. This feature allows efficient detecting and locating of insulation defects in GIS, by analyzing the time of arrival of the PD pulse to two PD sensors in GIS. Due to this fewer sensors can be used on the monitored equipment. PD signal measuring in

    Get Price
  • Measuring partial discharge in GIS | Think Grid

    The PDwatch Online UHF monitoring system records and displays the UHF signals generated by partial discharges in a gas insulated substation. It is permanently fitted into the substation and can be interrogated remotely at any time. This makes it possible to detect and eliminate emerging dielectric faults before a flashover can occur.

    Get Price
  • GIS - Home | PMDT

    Our Online Partial Discharge (OLPD) testing and monitoring technology can identify dangerous PD activity in GIS and monitor any further insulation deterioration caused by PD activity. During production, operation or when maintenance work is performed, the surfaces of conductors can be soiled or

    Get Price
  • De-noising of partial discharge signal using wavelet

    Detection and analysis of partial discharge (PD) have been regard as the most effective method for condition monitoring and asset management of gas-insulated structures (GIS) in the power system. However, PD detection sensitivity and accuracy are greatly influenced by on-site noise and interference, resulting in failures in PD severity assessment, defect identification or localization.

    Get Price
  • SF6 EMISSION REDUCTION FROM GAS INSULATED

    Therefore, Gas insulated equipment like gas circuit breaker (GCB), gas insulated switchgear (GIS) and gas insulated transformer (GIT) are being widely and commonly applied. Particularly in Japan where the land acquisition is extremely difficult, there is a large demand for gas insulated equipment as above.

    Get Price
  • Vibration Fault On-site Dection of Gas-insulated

    At present, GIS equipment (gas insulated switchgear) is more and more popular in power system, and the detection of GIS faults is mainly aimed at discharging faults. But more and more phenomena show that mechanical faults can not be ignored.

    Get Price
  • A Study on a Miniaturized Planar Spiral Antenna for

    for detecting PD in gas insulated substations (GISs), which is sine-wave meandered based on the traditional Ar- chimedean spiral antenna in order to reduce the antenna’s size. The test results

    Get Price
  • Mechanical defects diagnosis for gas insulated switchgear

    1. Introduction. SF 6 gas insulated switchgear (GIS) has been widely used in high voltage power system substations due to its compact size, high reliability, and superior performance , .GIS integrates circuit breakers, current transformers, voltage transformers, surge arrestors, etc. Faults may occur in the GIS and cause gas leakage, insulation failure, etc., which may damage the equipment and

    Get Price
  • New aspects of UHF PD diagnostics on gas-insulated

    Oct 23, 2014Abstract: Gas insulated switchgears (GIS) have been increasingly introduced as main substation equipment since the late 1960s thanks to their high reliability, safety, and compactness. The UHF method to diagnose partial discharge (PD) is broadly employed in the field as an advanced insulation diagnostic technology.

    Get Price
  • Gas Insulated Switchgear Solutions | JST Power Equipment

    C-GIS – Is a robust, industrial optimized medium voltage solution utilizing SG6 gas as an insulating medium. C-GIS is offered in a wide range of ratings designed for use in primary distribution applications. We offer a variety of panel configurations at the following preferred ratings: 40.5kV / 1,250-2,500A / 31.5kA; 12-24kV / 1,250-2,500A / 25-31.5kA

    Get Price
  • Preparation and Application of TiO 2 Nanotube Array Gas

    Jun 18, 2016This review presents an introduction to the sensor applications of TiO 2 nanotube arrays (TNTAs) in sulfur hexafluoride (SF 6)-insulated equipment, which is used to evaluate and diagnose the insulation status of SF 6-insulated equipment by detecting their typical decomposition products of SF 6: sulfur dioxide (SO 2), thionyl fluoride (SOF 2

    Get Price
  • Detection and Diagnosis of Defect in GIS Based on X

    For better application of X-ray digital imaging technology in defect detection in Gas Insulated Switchgear (GIS), it is essential to investigate the typical defect and establish the defect

    Get Price
  • Global Transmission Report : China XD to supply equipment

    Oct 16, 2012Under the CNY2.06 billion contract, XD Electric’s six subsidiaries will supply AC equipment including converter transformers, converter valves, gas-insulated switchgear (GIS) and disconnecting switches. The delivery of equipment would start from February 2013 and will be completed by end-March 2014.

    Get Price
  • China Conductor and Cable and Wire - China Jinshui, Cable

    Advanced equipment and technology first-class, complete detection means. 680 employees, including 20 senior technicians, 72 middle-level technicians, 588 skilled workers. Annual production capacity of 800,000 kilometers, equivalent to about 30,000 tons of copper electrical.

    Get Price
  • The SF6 Decomposition Mechanism: Background and

    Jan 24, 2017Gas-insulated equipment using SF 6 as insulation and arc extinguishing media such as gas-insulated station (GIS), gas-insulated transformer (GIT), and gas-insulated line (GIL) has been widely used in the field of high voltage and extra-high and ultra-high voltage power systems. It gradually became the most ideal equipment and one of the important symbols of modern substation because

    Get Price
  • GDPD-GIS/OL Partial Discharge Online Monitoring System of

    Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid.

edge-iconRelated News
toTop
Click avatar to contact us