October 201 New Range of Rapidox sf 6 Gas Analysers are Launched in China. Cambridge Sensotec announced the launch of their new Rapidox sf6-gas 6100 Pump Back gas analyser at the EP China Exhibition in Beijing this month. The analyser is designed for monitoring sf 6 gas within medium and high voltage gas insulated electrical equipment. EP China is an international event organised by the China ...

[email protected]
News Detail
  • SF6 Product Guide - cambridge-sensotec.co.uk

    2018-11-11Rapidox SF6 6100 analysers, alongside a range of stainless steel braided hoses. All components fit neatly inside the heavy-duty IP66 case. Rapidox Configuration The Rapidox SF6 6100 Pump Back and Portable gas analysers can be configured to the individual customers requirements, with a range of compatible gas sensing combinations available.

    Get Price
  • Rapidox SF6 Fixed Detection System - Cambridge Sensotec

    SF6 Fixed Detection System The Cambridge Sensotec SF6 Fixed Detection System is a wide area monitoring solution to ensure safety for personnel working in, or who have access to, rooms that contain high voltage switchgear, circuit breakers and transformers where SF6 is at high pressure; it is important to monitor for leaks continuously.

    Get Price
  • SF6 6100 Pump Back Gas Analyser - SF6 Gas Analysis |

    2020-8-11The Rapidox SF6 6100 is housed neatly into a tough Peli transport case supplied with special tongue and groove self sealing couplings, which are compatible with famous brands. Once powered and connected, the Rapidox automatically removes a small quantity of gas from the electrical equipment, controlled with an auto gas pressure sensing function. A

    Get Price
  • SF6 Gas Analysis - Cambridge Sensotec

    2019-9-6network and ISO 9001 accreditation. The company’s Rapidox SF6 gas analyser range is designed for many applications including the testing of high voltage gas insulated electrical equipment, medical monitoring, process gas analysis and SF6 gas purity testing. Rapidox SF6 6100 Pump Back Fully automated and highly configurable, the Rapidox SF6 6100

    Get Price
  • Rapidox SF6 6100 Pump Back Automatic Multigas Analyser

    2021-1-8Rapidox SF 6 6100 Pump Back Automatic Multigas Analyser Features Portable field instrument housed in a heavy duty IP66 Peli transport case. Total weight: 17kg No waste or emissions emitted during the testing of SF 6 purity Powerful 10 bar compressor returns SF 6 gas to the electrical equipment at a high pressure

    Get Price
  • Rapidox SF6 6100 Bench Technical Datasheet - Cambridge

    A gas output nozzle allows for the analyser to be attached to the Rapidox Gas Recovery Bag, ensuring that all sampled SF6 gas is recovered. The Rapidox SF6 6100 Bench analyser is also available as a complete and portable kit, allowing users to carry all of the equipment that they need within a

    Get Price
  • Rapidox SF6 6100 Bench Troubleshooting - SF6

    Troubleshooting details for the Rapidox SF6 6100 Bench gas analyser. English. Chinese (Simplified) Measuring moisture in gas is a slow process because the sensor surface has to dry out in the measurement gas to give a correct reading. This will load the factory calibration back into the Rapidox.

    Get Price
  • Cambridge Sensotec launch the new range of Rapidox SF6

    October 201 New Range of Rapidox SF 6 Gas Analysers are Launched in China. Cambridge Sensotec announced the launch of their new Rapidox SF 6 6100 Pump Back gas analyser at the EP China Exhibition in Beijing this month. The analyser is designed for monitoring SF 6 gas within medium and high voltage gas insulated electrical equipment. EP China is an international event organised by the China

    Get Price
  • Correlation analysis between SF6 decomposed components

    To obtain and understand the decomposition characteristics and decomposition process of SF 6 gas under different negative DC voltages, a physical model of the needle‐plate defect is used to conduct decomposition experiments of SF 6 gas. Experimental results show that, under different negative DC voltages, the partial discharge (PD) caused by the needle‐plate defect decomposes SF 6 gas and

    Get Price
  • SF6 positive DC partial discharge decomposition

    The condition monitoring and fault diagnosis method based on decomposed component analysis (DCA) for SF 6 gas‐insulated equipment, which mainly aiming at AC SF 6 gas‐insulated equipment, has become a research hotspot. Therefore, SF 6 positive DC partial discharge (PD) decomposition experiments under four typical insulation defects were conducted in this work.