Highly sensitive current transformer tester

Highly sensitive current transformer tester

The Single-phase TTR (Transformer Turn Ratio) Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit.

[email protected]
News Detail
  • TTR550005B - Single phase hand cranked transformer turns

    The TTR test set aids in identifying: Shorted coils; Open circuits; Incorrect connections; Internal faults or tap-changer defects in step regulators as well as in transformers; The instrument measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1.

    Get Price
  • TTR550005B - Single Phase Hand Cranked Transformer Turns

    The TTR test set aids in identifying: Shorted coils; Open circuits; Incorrect connections; Internal faults or tap-changer defects in step regulators as well as in transformers; The instrument measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1.

    Get Price
  • 550005B Megger Transformer Turns Ratio Tester New

    The single-phase, hand-cranked model measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1. The TTR set operates on the principle that the voltage ratio of the transformer at no load isBrand: Megger

    Get Price
  • Transformer Testing Equipment handheld,lightweight robust

    The Single Phase Transformer Testing Equipment TTR, Transformer Turns Ratio Test Set, measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit. The TTR test set aids in identifying:Reviews: 57

    Get Price
  • Transformer Maintenance and Diagnostics Using Frequency

    Test circuit ground is considered to be the tank of the transformer under test. The traditional technique is to measure and record the exciting impulse and the resulting response current using a digitizer with sufficient amplitude resolution (generally accepted as at least 9 bit, or 1 part in 512 resolution), and sufficient sampling rate to preserve the highest frequency to be included in the transfer function result.

    Get Price
  • On Sale! Megger 550005B Transformer Turns Ratio Tester

    Megger 550005B Transformer Turns Ratio Tester The Single-phase TTR Transformer Turns Ratio Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit.

    Get Price
  • WR Series - Current transformers - Bender

    The highly sensitive WR…S series measuring current transformers of rectangular type convert AC currents into evaluable measurement signals, in combination with RCM and RCMS series ground-fault monitors and evaluators.Category: Products Current Transformers

    Get Price
  • Sanjay Electrical Traders, Bhagirath Palace

    Current Transformer accurately measure electrical current. It utilizes the strength of the magnetic field around the conductor to form an induced current that can then be applied across a resistance. We are India based renowned supplier and retailer of huge range of current power transformers.

    Get Price
  • DTTS Distribution Transformer Test System - HV Technologies

    State of the art frequency converter (up to 200 Hz) Powerful operating software with intuitive interface and automated test sequences. The highest accuracy and the only completely calibrated and certified measurement system. The lowest system noise level allowing highly sensitive

    Get Price
  • Transformers - All Manufacturers - eTesters.com

    High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change.

    Get Price
  • Distribution Transformer Test System Leaflet

    Thelowestsystem-noiselevelallowinghighlysensitivePartial Dischargemeasurements Powerfuloperatingsoftwarewithintuitiveinterfaceandautomated testsequences Distribution transformers are “mass production equipment”; high testing-throughput is a must without compromising quali- ty.

    Get Price
  • Transformer Maintenance and Diagnostics Using Frequency

    This technique by design inserts the current measuring cable impedance in series with the transformer winding under test, thereby making the result highly dependent on the particular length and characteristics of the cable. In addition, the relatively high 50 ohm impedance significantly damps the high frequency portion of the FRA response.

    Get Price
  • Amazon.com: current sensor

    Non-Contact AC Voltage Tester/Voltage Tester Pen with Adjustable Sensitivity, LCD Display, LED Flashlight, Buzzer Alarm, Dual Range 12V-1000V/48V-1000V Live/Null Wire Judgment - TACKLIFE VT02 XLX 2PCS ACS712 20A AC and DC Current Sensor Module ACS712-20A Module Highly Sensitive High Efficient (20A) 3.8 out of 5 stars 13. $8.99 $ 8. 99

    Get Price
  • Megger 550005B Single Phase Hand-Cranked Transformer

    The unit measures turns ratio from 0.001 to 129.99 and excitation current from 0 to 1A, making it suitable for measuring highly sensitive windings and other electrical equipment. It can also be used to test three-phase transformers by connecting it to each phase separately. The 550005B is used by electricians and electrical contractors.

    Get Price
  • Provided by www.AAATesters.comSingle-phase, Hand

    The Single-phase TTR Transformer Turns Ratio Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit. The TTR test set aids in identifying: n Shorted coils n Open circuits

    Get Price
  • Spot testing of transformer by TECHIMP – Altanova

    4 mins readOct 15, 2019The online testing was performed by using TECHIMP – ALTANOVA GROUP make AQUILA; a portable PD equipment for spot testing as well as temporary monitoring, and its highly sensitive HFCT (high frequency current transformer) sensor with very high transfer impedance of 19mV/mA, clamped on the cable grounding sheath or bonding cables.

    Get Price
  • Megger 550005B Single-Phase, Hand-Cranked TTR

    The TTR test set aids in identifying: Shorted coils; Open circuits; Incorrect connections; Internal faults or tap-changer defects in step regulators as well as in transformers. The single-phase, hand-cranked model measures highly sensitive turns ratios of up to 129.99:1 with accuracy of +/- 0.1%.

    Get Price
  • Megger 550005 Transformer Turn Ratio (TTR) | ATEC

    The Single-phase TTR (Transformer Turn Ratio) Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit.

    Get Price
  • Transformer Turns Ratio Test Sets

    • Measures highly sensitive turn ratios up to 129.99:1. An optional auxiliary transformer extends this ratio range to 329.99:1. SPECIFICATIONS Three-Phase Model Output •120 volt, 50/60 Hz standard test for power and distribution transformers •40 V, 50/60 Hz for current transformers Selector switches provide automatic selection of transformer winding

    Get Price
  • Megger 550005B Single-Phase, Hand-Crank Transformer

    The unit measures turns ratio from 0.001 to 129.99 and excitation current from 0 to 1A, making it suitable for measuring highly sensitive windings and other electrical equipment. It can also be used to test three-phase transformers by connecting it to each phase separately. The 550005B is used by electricians and electrical contractors.Brand: Megger

    Get Price
  • WS…/WS…-8000 series - Current transformers - Bender

    In addition, the measuring current transformers can be used in combination with insulation fault locators (EDS) for IT systems. They are designed to measure the test current generated by a PGH locating current injector or an ISOMETER IRDH. In combination with EDS series insulation fault locators the test current is converted into evaluable

    Get Price
  • Oil Tester, Oil Tester Sets, Automatic Oil Testers, Mumbai

    Manufacturing, Dealing Activities In The Field Of Electronics Electrical Testing And Measuring Instruments, H V Test Sets, Automatic Oil Tester, Microprocessor Based Oil Test Set, Microprocessor Based Oil Test Set Semi Automatic, Current Injection Sets, Portable Relay Test Sets, Transformer Ratio Meters / TRM 1000, Mumbai, India

    Get Price
  • Megger 550005B Single-phase, Hand-cranked

    Measures highly sensitive turn ratios up to 129.99:1. An optional auxiliary transformer extends this ratio range to 329.99:1. AVO Biddle Meggers. Single-phase TTR Transformer Turns Ratio Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate

    Get Price
  • PD-SGS: On-line Partial Discharge Spot Tester - IPEC LTD

    Handheld Partial Discharge Spot Tester. The PD-SGS is an on-line partial discharge spot tester for HV assets. The instrument detects TEV signals generated by internal discharge in Air Insulated Switchgear (AIS), acoustic discharge generated by surface tracking or corona, high frequency signal generated by cable partial discharge, and ultra-high frequency signal generated by internal discharge

    Get Price
  • Single-phase, Hand-cranked TTR Transformer Turns Ratio

    transformer. It can be used to test three-phase transformers by connecting and testing each phase separately. FEATURES AND BENEFITS . n. Provides unmatched accuracy (±0.1%) in a portable de-sign. n. Packaged in a rugged, compact case. n. Measures highly sensitive turn ratios up to 129.99:1. An optional auxiliary transformer extends this ratio range to. 329.99:1.

    Get Price
  • Megger 550005B Transformer Turns Ratio Test Set

    Ratiometers Megger 550005B Transformer Turns Ratio Test Set Single-phase, Hand-cranked TTR, 0.001 to 129.999 range, precision bridge measuring technique.

    Get Price
  • Advanced Test Equipment Rentals

    transformer. It can be used to test three-phase transformers by connecting and testing each phase separately. FEATURES AND BENEFITS n Provides unmatched accuracy (±0.1%) in a portable de-sign. n Packaged in a rugged, compact case. Measures highly sensitive turn ratios up to 129.99:1. An optional auxiliary transformer extends this ratio range to 329.99:1.

    Get Price
  • Three Tips for Reducing Wasted Time When Testing

    Sep 30, 2019Without a doubt, the transformer test that customers most struggle with is the transformer Power Factor test (which includes the Overall Test, the Bushing C1 Test, and the Bushing C2 Test). Unfortunately, the Power Factor test is highly sensitive to the test environment, to the test lead connections, and to the test specimen’s earth-ground

    Get Price
  • [Biddle 550027] Avo Megger Ttr Transformer Turn

    Reference transformer: this is a tapped transformer having precise turn count at each tap and designed so that the primary voltage drop due to magnetizing current negligible when excited 8 volts. Detector: a phase-sensitive null-detector is used. Line operated model for shop or field testing is packaged in a rugged, wood en case.