News Center
Microsense gas insulated substation leak testing

Microsense gas insulated substation leak testing

Guide to Good Leak Testing - US EPA2013-2-4Allowed under the F Gas Regulations. Electronic leak detector Good for most leaks if the detector is used and maintained correctly (see Section 3 below). Make sure your detector is sensitive to the refrigerant type you are testing. Allowed under the F Gas Regulations – the leak detector must have a sensitivity of 5 g/year and should be checked

[email protected]
News Detail
  • Gas-Insulated-Substations SF6 gas handling

    2011-9-26IEC 62271-203 High-voltage switchgear and controlgear – Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (09/2011) Örequired leakage rate <0.5% / year / gas compartment tt f th td i 01%/ / t t ¾Extreme low emissions protect the environment state-o - e-art design <0.1% / year / gas compartment Axial direction

    Get Price
  • Gas-Insulated Substations - GIS

    6 mins read2021-3-7A gas-insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase-tophase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures. The atmospheric air insulation used in a

    Get Price
  • An Introduction to Gas Insulated Electrical Substations

    2020-10-6What is a Gas Insulated Substation? A gas insulated substation (GIS) is a high voltage substation in which the major conducting structures are contained within a sealed environment with a dielectric gas known as SF6, or sulfur hexafluoride gas as the insulating medium. In comparison, a conventional (AIS) or Air-Insulated Substation, atmospheric air is the

    Get Price
  • CONSTRUCTION DESIGN FEATURES OF GAS INSULATED

    Very fast transient over voltage (VFTO) is a unique electromagnetic transient phenomenon occurring in Gas Insulated Substation (GIS), which determines the insulation level of the GIS (above 330 kV).

    Get Price
  • SF6 gas Mixtures testing for Substation

    May 25, 2019A gas-insulated substation (GIS) uses a superior dielectric gas, SF 6, at moderate pressure for phase-to-phase and phase-to-ground insulation.The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF 6 gas inside grounded metal enclosures.

    Get Price
  • News Room : GE Grid Solutions

    A 245 kV gas-insulated current transformer; several of these products have been delivered and are now being installed at a customer’s site for testing in the network. A 145 kV gas-insulated substation, in which g3 is applied not only as an insulation medium but also as a switching and arc-quenching gas. This article is mainly about this product.

    Get Price
  • Measuring partial discharge in GIS | Think Grid

    The new sensor has been fitted in all types of Alstom Grid gas-insulated substation and tested for use in retrofit projects. These latest developments have resulted in an adapted version of the sensor being used in large power transformers to monitor partial discharges in oil.

    Get Price
  • Guide to Good Leak Testing - US EPA

    2013-2-4Allowed under the F Gas Regulations. Electronic leak detector Good for most leaks if the detector is used and maintained correctly (see Section 3 below). Make sure your detector is sensitive to the refrigerant type you are testing. Allowed under the F Gas Regulations – the leak detector must have a sensitivity of 5 g/year and should be checked

    Get Price
  • sf6 gas Gas Mixture Treatment for Substation

    Sulfur Hexafluoride, or SF6, gas leak testing is the newest in a series of innovative services being offered by Premier Utility Services LLC, a wholly-owned subsidiary of Willbros Group, Inc., to assist electric utilities in reducing overall maintenance cost, increasing reliability scores and protecting. Get Price

    Get Price
  • LNG Carrier Cargo Tank Tightness Test - SGS

    2016-2-17LEAK TEST METHODS n Ammonia (NH3) Leak Testing This test is performed by introducing an inert gas mixed with ammonia to the internal space of the test material and then over-pressurising. After ammonia sensitive paint is spread over the welding seams to be tested, the inert nitrogen/ammonia mixture gas is fed internally through the test

edge-iconRelated News
toTop
Click avatar to contact us