Apr 14, 2020Schneider Electrics to UC4: EPES Cyber-defence against Coordinated Attacks. Schneider Electric, as leader in energy and automation digital solutions collaborates in the H2020 SDN-microSENSE project. Schneider Electric is focusing its contribution on one of the six use cases: "EPES Cyber-defence against Coordinated Attacks". The objective of the use case is to validate the SDN-microSENSE platform in an electrical substation

[email protected]
News Detail
  • GIS Substation Design and Execution HV and EHV GIS

    2014/04 - Houston - CED – GIS - 3 GIS introduction 1/7 SF6 properties 1/3 zA GIS is the implementation, within a complete HV substation, of the remarkable sulphur hexafluoride (SF6) properties in terms of voltage withstand and current interruption zSF6 main data zNeutral gas: insulators and live parts are perfectly protectedMicrosense

    Get Price
  • GIS for digital substations - Hitachi ABB Power Grids

    Hitachi ABB Power Grids GIS can be equipped with control, protection and communication feature for smooth integration into substation automation systems using IEC 61850. For connection to the IEC 61850-9-2 process bus, non-conventional instrument transformers (NCITs) for GIS with merging units are used for sampled values for protection and

    Get Price
  • Digital Substation | Energy automation and smart grid

    Substations are an integral component of power grids. They connect grids of differing voltage levels, and their controlling and coordinating function is vitally important to the stability of the overall system. That’s why they’re considered the heart of the power grid.

    Get Price
  • Basic Substation Configurations and the Components

    enclose substations with energized electrical conductors or equipment. n This metal fence grounding requirement may be accomplished by bonding the fence to the substation grounding grid or to a separate underground conductor below or near the fence line using the methods described in the NESC.Microsense

    Get Price
  • National Grid Substations Technical Specification NGTS

    This functional Specification covers all types of substation with equipment installed for use on 132, 275 and 400 kV 50 Hz systems. It is applicable to both open-terminal air-insulated (AIS) and metal-enclosed gas-insulated (GIS) substation constructions and covers equipment operated at lower voltages on the same substation site.

    Get Price
  • The basics of Gas Insulated Substation (GIS) for students

    Nov 22, 2018The grounding and disconnect switches, needed in both air and gas insulated arrangements, will have view ports in gas isolated devices. GIS has a reduced “footprint” than a corresponding air insulated substation, usually less than half the area. Even though a gas isolated substation will initially cost more than a similar air insulated substation, the economics may

    Get Price
  • Gas Insulated Substation Definitions and Basics

    “Gas Insulated Substations.” In IEEE C37.122 Gas insulated switchgear (GIS): a compact, multicomponent - device, enclosed in agrounded metallic case in which the basic insulating medium is SF6 gas and which icallytyp includes buses, switches, circuit breakers, and other related devices.Microsense

    Get Price
  • E-045 Gas Insulated Substation Definitions and Basics

    C37.100.1 or in IEC 62271-1 standards for switchgear devices. For elements of high voltage switchgear like GIS, the ratings in the standards are followed to make criteria and applications in the field. The arrangement of GIS has to consider that the design and production costs of the metallic cases as pressure vessels of the GIS apparatus are huge.

    Get Price
  • Electrical Substation: Equipment, Types, Components

    The substation buses are current-carrying devices that interconnect the individual pieces of substation equipment. Busbar in HV Substation. The substation bus tubing (or bus bar) is aluminum or copper. Steel structures provide support for insulators, which are used to terminate lines, and support buses.Microsense

    Get Price
  • The history of gas-insulated substations | Think Grid

    The gas-insulated substation (GIS) represents a key element of high voltage electrical transmission networks thanks to its reliability, low maintenance requirements and compact dimensions. Here is a brief history of its development and pioneers.

    Get Price
  • CONSTRUCTION DESIGN FEATURES OF GAS INSULATED

    Gas insulated substations (GIS) have become a major component of power networks and have been used with considerable success over the past 40 years.

    Get Price
  • Electrical Equipment Used at Electrical Substations

    Electrical equipment used in any substation depends upon the following factors: Type of electrical substation- whether it is a Generating station, Transformer sub-stations, Switching Sub-stations etc. Design of the Substation, Service requirement; Degree of protection required; However, in general, any typical sub-station has the following main

    Get Price
  • Distribution Substations

    Distribution substation A distribution substation transfers power from the transmission system to the distribution system of an area. The input for a distribution substation is typically at least two transmission or subtransmission lines. Distribution voltages are typically medium voltage, between 2.4 and 33 kV depending on the size of the area served and the practices of the local utility.

    Get Price
  • Gas-Insulated Substations - GE Grid Solutions

    B105. Gas-Insulated Substations up to 300 kV. GEs B105 GIS is a compact, field-proven solution with high availability that meets the challenges of networks up to 300 kV for power generation, transmission, distribution, tertiary and heavy industry applications. The B105 is available in several ratings: 253 kV, 50 kA, 4000 A. 253 kV, 63 kA, 4000 A.

    Get Price
  • GIS or Gas Insulated Switchgear | Electrical4U

    Oct 23, 2020It is very much required to establish an electrical substation at load center. Since, establishing a substation at load center is quite economical and profitable in many aspects. As it reduces length of feeders and due to short length feeders, the quality of voltage regulation improves. But the main obstruction of establishing a substation at load center is space.Microsense

    Get Price
  • Substation Training - The Electricity Forum

    Our 12-Hour Live Online Substation Training course will cover the major elements that build electrical substations and switchyards. This 12-Hour Live Online Substation Training course give an overview of substations, primary breaking device, transformer, secondary switching devices, switchgear lineup, instrument transformers, relays, meters instruments, lightning arresters, transducers

    Get Price
  • Schneider Electrics to UC4: EPES Cyber - SDN microSENSE

    Apr 14, 2020Schneider Electrics to UC4: EPES Cyber-defence against Coordinated Attacks. Schneider Electric, as leader in energy and automation digital solutions collaborates in the H2020 SDN-microSENSE project. Schneider Electric is focusing its contribution on one of the six use cases: “EPES Cyber-defence against Coordinated Attacks”. The objective of the use case is to validate the SDN-microSENSE platform in an electrical substation

    Get Price
  • INTEGRATION OF SUBSTATION DATA - CIMug

    that typically occurs between substation devices. Rather, it is to provide a migration strategy so that existing equipment and control center applications can be operated in a more profitable and reliable manner. 1.1 Unified Data Access Most substation data comes from substation devices. All substation devices

    Get Price
  • Substation of the future | References | Siemens Energy Global

    Designing a modern, environmentally friendly, yet compact substation. To meet the customers requirements, the latest innovations from Siemens were chosen. This includes the worlds first SF 6 -free gas-insulated switchgear (GIS) with a rated voltage of 145 kV. As part of Siemens’ blue portfolio, the GIS is insulated with Clean Air.

    Get Price
  • Gas Insulated Substation - definition - English

    The present invention relates to a method for the ultra-high-frequency (UHF) measurement of a partial discharge (PD), wherein said measurement is carried out using an ultra-high-frequency sensor (C) at at least one point of a gas-insulated substation (GIS), characterized in that the point is selected at at least one porthole (H) of said substation and in that the ultra-high-frequency sensor (C) is in contact withMicrosense

    Get Price
  • Substations - an overview | ScienceDirect Topics

    Collector substation: usually step up transformer, generally are connected to increase the level of power from the generation level, for example, in wind fields for the high power level consumers. 4. Converter substation: these devices can change some important parameters like frequency of

    Get Price
  • Transformer Substation | Types Of Transformer Substation

    A transformer substation is a part of the electrical installation that includes the terminations of the transmission or distribution lines and switchgear. It contains one or more transformers as the central part. The substation also typically includes all the necessary devices

    Get Price
  • Gas-Insulated Substation e-learning – GE Grid Solutions

    Understand the role of HV Gas-Insulated Substation, and gain insight on components and transformers. Topics. GIS circuit breaker: interrupting chamber breaking sequence, technological advancements, control monitoring Protection Devices (Lightning Arrester, Buchholz Relay, Pressure Relief Device…

    Get Price
  • Product brochure Gas-insulated switchgear ELK-04 C,

    dard defines strict rules for realizing interoperability between functions and devices used for protection, monitoring, control and automation in substations. GIS from ABB are built on 50 years of pioneering research and development and experience delivering over 25,000 switchgear bays in

    Get Price
  • Design Guide for Rural Substations

    United States Department of Agriculture Rural Utilities Service RUS Bulletin 1724E-300 Issued June 2001 Design Guide for Rural SubstationsMicrosense

    Get Price
  • Gas-Insulated Switchgear (DC-GIS) | Gas-insulated

    Siemens GIS operate safely and reliably even under severe climatic conditions, which means that a gas-insulated substation doesn’t require an extra housing in most cases. The comprehensive range of standardized modules available helps implement even complex arrangements and switchyard layouts without much interface engineering, while commissioning of the GIS switchgear is fast and cost-efficient.

    Get Price
  • Gas-insulated switchgear from 72.5 to 550 kV

    All Siemens GIS control and protection devices fully comply with the IEC 61850 standard, which has been defined in a mutual effort of customers and manu-facturers to create a uniform, non-pro-prietary, and future-proof basis for digital substation automation and control com-munication. Siemens control and protection devices

    Get Price
  • interview questions | InterviewAnswers

    Job interview questions and sample answers list, tips, guide and advice. Helps you prepare job interviews and practice interview skills and techniques.Microsense

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online